Dimension effect on low strain integrity testing of prestressed pipe piles
-
Graphical Abstract
-
Abstract
In this paper,based on the comparison and analysis of velocity curves got from tests or numerical calculation,a formula is obtained for time difference among the initial velocity signals at different points.From the viewpoint of vibration mode,the fact is explained that high frequency disturbing signals at different points are weakened and changed when the load impulse changes.At last some signals from defect pipe piles are studied.
-
-