Calculation of the horizontal coefficient of subgrade reaction with the flat dilatometer test
-
-
Abstract
The horizontal coefficient of subgrade reaction,Kh, plays a significant role in problems dealing with laterally or loaded piles, excavation and tunnel engineering. The calculation formula for the horizontal coefficient of subgrade reaction is derived from the principle of the flat dilatometer test. And the influence factors of Kh, such as the width and shape of foundation, the rigidity and plexibility of the foundation and the rate of loading are considered respectively.then,the values of Kh are obtained from the calculation formula according to the data of insitu DMT in Shanghai,and the calculated values of Kh are almost equal to those suggested in the code.
-
-