慕焕东, 邓亚虹, 张文栋, 宋登艳. 洛阳地铁车站基坑支护变形特性模型试验研究[J]. 岩土工程学报, 2021, 43(S1): 198-203. DOI: 10.11779/CJGE2021S1036
引用本文: 慕焕东, 邓亚虹, 张文栋, 宋登艳. 洛阳地铁车站基坑支护变形特性模型试验研究[J]. 岩土工程学报, 2021, 43(S1): 198-203. DOI: 10.11779/CJGE2021S1036
MU Huan-dong, DENG Ya-hong, ZHANG Wen-dong, SONG Deng-yan. Model tests on deformation characteristics of foundation pit at Luoyang Railway Station[J]. Chinese Journal of Geotechnical Engineering, 2021, 43(S1): 198-203. DOI: 10.11779/CJGE2021S1036
Citation: MU Huan-dong, DENG Ya-hong, ZHANG Wen-dong, SONG Deng-yan. Model tests on deformation characteristics of foundation pit at Luoyang Railway Station[J]. Chinese Journal of Geotechnical Engineering, 2021, 43(S1): 198-203. DOI: 10.11779/CJGE2021S1036

洛阳地铁车站基坑支护变形特性模型试验研究

Model tests on deformation characteristics of foundation pit at Luoyang Railway Station

  • 摘要: 以洛阳火车站地铁车站明挖基坑支护工程为背景,对基坑开挖过程中支护结构侧向位移变化规律开展3组小比尺模型试验,探讨基坑开挖后基坑支护桩身位移变化规律并考虑不同桩间距的影响。研究结果表明,桩身位移随着基坑深度的增加在基坑边缘处为先增大后减小,在基坑中间部位为先缓慢增加后急剧增加,最大桩身位移深度为距基坑底部1/6基坑深度处,桩身位移达3.91 cm;桩身位移随着地面荷载的增加逐渐增大,且距基坑顶部1/6处桩身位移变化幅度较小,最大桩身位移为1.8 cm,随着距离增加至距基坑顶部1/2处桩身位移变化幅度增加了41.1%,最大桩身位移为2.54 cm;当距离增加至距基坑底部1/6处桩身位移变化幅度急剧增大,最大桩身位移为3.91 cm,相比基坑顶部1/6处增加近1.2倍。研究成果对洛阳地铁火车站深基坑工程设计具有重要指导意义。

     

    Abstract: With the support project of open-cut foundation pit of Luoyang Railway Station as the background, three groups of small-scale model tests are carried out to study the variation of lateral displacement of support structures of foundation pit during the excavation process, and the variation law of displacement of support piles after excavation and the consideration of the different pile spacings are discussed.The results show that the displacement of piles increases first and then decreases with the increase of the depth of foundation pit, and increases slowly and sharply in the middle of foundation pit.The maximum displacement depth of piles is 1/6 of the depth of foundation pit at the bottom of foundation pit, and the displacement of piles reaches 3.91 cm.The displacement of pile body increases with the ground load.The maximum displacement of piles is 1.8 cm.The displacement of piles increases by 41.1%and the maximum displacement of piles is 2.54 cm as the distance increases to 1/2 of the top of foundation pit.When the distance increases to 1/6 of the bottom of foundation pit, the displacement of piles increases sharply.The maximum displacement of piles is 3.91 cm, which is nearly 1.2 times larger than that of the top 1/6 of the foundation pit.The research results have important guiding significance for the design of deep foundation pit of Luoyang Railway Station.

     

/